本篇目录 12 节 · 展开 ▾
Chapter 1 Introduction
This paper's Introduction defines the basic idea of carrying out an energy cost audit for chain flower shops. The first type of energy cost audit is a structured, documented process that will quantify, check, and analyse how much power, water, and gas is used in a company; then it will show the distribution of costs, any anomalies in use, and ways to cut down expenses [1]. Energy cost audits are not concerned with whether the books are correct or compliant; they are only to find out how much energy is consumed and the corresponding expenditures, and thus determine whether there is a problem with business operations that need to be adjusted.
The core reason for this is that the energy use of the retail environment has some characteristics in terms of equipment, time, etc. In chain flower shops, the main utility loads are commercial refrigeration units used to preserve cut flowers, lighting systems that serve display and plant care, climate control equipment, and water supply for plant maintenance. As a result of the uniformity of the loads at all standard stores, small changes in the consumption of a single store can be used to judge whether there is an equipment failure or irregular operation mode or low efficiency in scheduling. It is this predictability that makes an audit practical and useful; comparing the performance of one store to others will produce concrete data for managers to use.
Generally, this sort of audit will be carried out in accordance with the procedure. It starts with collecting data on utility bills, meter readings, and equipment inventories for a representative period, usually twelve months, to show how things change with the seasons. Consumption analysis is carried out in the second stage, and the amount used is compared with the relevant factors of the floor area, sales volume, refrigeration capacity, etc., so that different branches can be fairly compared. At the third stage, on-site verification will be conducted to check whether the recorded consumption is correct based on the condition of the equipment and operating hours of the staff. Finally, at the stage of reporting and making recommendations, the issues found will be solved by adjusting the refrigeration temperature setpoints, replacing old lights, etc.; the cost savings and payback period of each solution will also be given [4].
The above steps are important for the practical operation of the chain flower shop business. First, utility costs are a regular, manageable expense; small percentage reductions will accumulate significantly in all branches. Second, flower preservation depends heavily on refrigeration, so the energy audit indirectly protects product quality by revealing that the equipment is not operating within the intended range. Third, due to low margins and fierce competition in this industry, strict cost control can enhance the price flexibility of the enterprise and improve its overall financial situation. Fourth, the regular audit system allows the headquarters to compare the branches relatively and fairly evaluate their performance and provide targeted staff training. Finally, the systematic energy management of the enterprise will be in line with the general public's requirements for sustainability and the industry's regulations on the use of electricity. Therefore, this paper analyses the audit process in detail to build a simple, standardised method that is suitable for the operation of chain flower shops and other small-format retail chains.
Chapter 2 Process Analysis of Utility Energy Cost Auditing in Chain Flower Shops
2.1 Characteristics of Energy Consumption in Chain Flower Shop Operations
There are differences in the energy use of chain flower shops, so the design of the utility cost audit should be different for each type of shop. The main purpose of refrigeration in a large number of stores is to store cut flowers that need to be kept at low temperatures for freshness. Therefore, there are refrigerated display cases and back-room cold storage units that are always running, 24 hours a day, regardless of how many customers are in the store. Since a compressor-driven refrigeration system will not stop abruptly, it will be one of the larger and more stable loads in the store's electricity bill; therefore, it is the first to be metered and tested for efficiency, etc., and adjusted according to the temperature set in the energy audit.
Secondarily, the purpose of air-conditioning is to provide a comfortable environment for customers in the sales area and suitable conditions for live plants and arrangement work. Lighting is another major type of load, including sales floor lights, window display lights that may be on for a long time to attract customers, and special grow lights used by stores selling potted plants to supplement lighting. Supporting loads are electric water heaters for cleaning and preparation work, as well as point-of-sale equipment such as cash registers, barcode scanners, computers, and payment terminals. Though small in themselves, the standby and operating power consumption of these auxiliary equipment in the chain is not negligible.
Compared with the single store, the structure of the chain is somewhat different and thus cannot be used to inspect all the stores in the network. Due to multi-site duplication, identical or nearly identical equipment will be used in many stores. If one store has a problem with the door seal, incorrect thermostat setting, or outdated lighting technology, it will likely spread to other stores in the network. This duplication can be used as an audit opportunity; the standardised measurement of some stores is used to derive conclusions and roughly estimate the overall savings of the chain. Secondly, operating hours in a chain flower shop are usually longer and relatively fixed due to the need for brand consistency, so the lighting, air conditioning and refrigeration will run longer, increasing the base consumption. Thirdly, the demand is highly seasonal. Around Valentine's Day, Mother's Day and other holidays, there will be an increase in the amount of refrigerated goods, the number of hours that employees work will be extended, the use of preparation equipment will increase, and the cooling demand will also rise; therefore, the electricity bill will be higher than average in these months. Therefore, an effective audit needs to use the data of the year-on-year trend adjusted for seasonality, not just the month-on-month average.
Based on the auditability perspective, the main cost categories are large in scale and can be measured by available records or instruments; thus, refrigeration electricity, air conditioning and lighting are the most relevant items for audit, and their consumption can be checked against sub-meter readings, nameplate data, operating schedules and utility bills. Auxiliary loads such as water heating and POS equipment are small, but they can still be audited by load inventory and usage time estimation. By identifying the above consumption characteristics, we can provide some empirical basis for the next audit procedures.
表1 Energy Consumption Characteristics Across Chain Flower Shop Operations
2.2 Framework and Workflow of the Utility Energy Cost Audit
A systematic assessment of the costs of power, water, gas and other utilities for all chain flower shops will be carried out as part of the general Energy Consumption Audit. At the root of the above principle is the need to form a traceable chain of evidence for all kinds of utility costs and their corresponding stores, time periods and business activities to prevent overstatement of expenditure in the books and concealment by omission. Because there are many small flower shops that have high refrigeration and lighting needs, utility costs are a large part of the expense and can be easily distorted; therefore, a standardised audit system is necessary to control costs and provide reliable financial information.
The audit framework is a closed-loop process that will be carried out step by step in seven stages. First, at the planning stage, the audit team will decide which stores will be audited, the period for the audit, and what kind of materiality to look out for; then, an audit checklist will be prepared. Data collected include utility bills, meter readings, lease contracts and the internal payment records of the headquarters and individual stores. Thirdly, Verification will examine whether the data collected is correct by comparing the utility invoices with the supplier's statements, meter readings and bank payment records to confirm that each expense actually took place. Fourthly, allocate shared utility costs, including the electricity used by common areas of the leased premises; they will be distributed reasonably based on area or metering at each store. Fifthly, Analysis will compare the actual utility costs with the budget, historical data and industry averages to determine if there are deviations; it may be due to wasted use, metering errors or fraud. Sixthly, Reporting will combine the results into a written Audit Report with concrete numbers about the problems and suggestions for improvement. The follow-up will monitor whether the corrective measures have been taken and whether the problems that have been detected have been solved.
Within this Workflow, the various duties and responsibilities are set out in detail. Finance staff at the headquarters will plan the audit, standardise data formats, carry out allocation calculations and consolidate reports. Store managers are responsible for providing accurate meter readings and original bills, explaining local abnormalities such as seasonal cooling demand for fresh flowers and taking corrective measures at the store level. The auditors are independent and will conduct verification and analysis, collect evidence, and report their findings objectively without any influence from the operation management.
A series of internal control checkpoints have been added to this process: the first is to grant permission for utility payments, and the second is to check whether there is an invoice and a meter that match in the two places. A risk-based sampling approach will be adopted, with stores that have large fluctuations, high consumption or old audit records being subject to full examination; otherwise, stable stores will be tested using a sample, and generally, twenty to thirty per cent of the stores will be chosen. Routine reviews of audits will be carried out once a quarter, and an annual comprehensive audit and targeted special audits will be added in case of any major problems; thus, a continuous monitoring system will be established while considering the costs and benefits of control.
表2 Framework Stages and Key Outputs of the Utility Energy Cost Audit
2.3 Data Collection and Cost Allocation Methods Across Store Locations
2.3.1 Metering and Billing Data Standardization
The first is the standardization of meter reading cycles. Outlets may be read monthly, bimonthly, or on irregular dates according to the local utility's schedule. To achieve an effective comparison, the audit process will be carried out to record the exact meter reading dates, meter serial numbers, and cumulative consumption numbers for each store, then convert all the consumption data into a normalized index, such as the daily average consumption per period. Remove the distortion caused by unequal billing intervals. If there are sub-meters for refrigerated display cases, air conditioners and sprinklers, they should be read at the same time as the main meter to help with later end-use attribution.
The second part is about the tariff structure. Electricity is often charged at peak and off-peak rates, and flower shops with refrigeration loads often use a large amount of electricity at night during off-peak hours, so the cost will be relatively high. Therefore, the standard template should be able to separate the consumption and costs of different tariff tiers, and also include demand charges, fixed fees, etc., and applicable taxes or surcharges. Water and gas prices are often tiered or seasonal; thus, it is necessary to record the volume consumed in each price tier rather than just the total invoice amount so that the auditor can distinguish between the effects of price and consumption.
The third part is to convert all the different kinds of billing forms into a single audit template. Paper invoices, electronic statements, and combined landlord fees are sent to the stores; their formats and units differ. The standardised template shall have fixed fields such as Store ID, billing period, reading dates, meter ID, category of consumption, per unit rate for each tariff tier, charge and payment status. All units should be changed to the same metric, such as kilowatt-hour, cubic metre and litre; if there is a packaged or estimated landlord charge, it needs to be broken down with a documented allocation key.
Finally, there should be verification and treatment for irregularities. Examine the arithmetic consistency of the bills with the meter records, ensure that the rates are applied correctly, and look at the changes over time. The estimated readings, which are identified by comparing them to the historical consumption patterns, will be indicated and replaced with actual readings for later periods if possible. Corrections and reissued invoices must be linked to the original entry to avoid double-counting. Missing data can be addressed by means of documented imputation, such as interpolation based on the conditions of comparable periods, weather or sales, and all adjustments should be recorded in the audit trail. This disciplined way of handling things will enable the allocation of expenses according to the actual consumption of the store and serve as the basis for a reasonable plan of saving energy in the future.
2.3.2 Allocation of Shared Energy Costs Among Outlets
In the operations of a chain flower shop, some energy costs cannot be directly borne by a single outlet, but are shared by all stores and billed by a third party. These shared expenses can be broadly divided into three types: shared cold storage facilities to preserve fresh flowers for several stores, headquarters office energy to support the company's administrative work, and utilities that are paid by the landlord or property management company, not by each shop. These costs will affect the accuracy of the utility cost audit, so the auditor should assign them reasonably and systemically to cost objects (i.e., individual stores).
The allocation basis is the first problem that needs to be solved. The bases are usually floor area, sales volume, refrigeration capacity, and metered sub-usage. The base of floor area is easy to apply and is suitable for office energy allocation, as the use of heating, air conditioning and lighting is generally in direct proportion to the space occupied. Sales volume reflects the principle of benefit-receiving and is suitable for shared administrative expenses; however, it distorts energy responsibility because energy consumption does not increase in line with revenue. Refrigeration capacity is measured by storage volume or compressor power; thus, it is the most appropriate basis for shared cold storage, as a larger refrigerated area requires more energy. Metered sub-usage can be installed with a sub-meter for the main equipment and is the most accurate attribution, so it should be used whenever possible.
A two-layered system of direct metering first and then allocation is often used in practice. In places where there are sub-meters, the costs will be directly borne by the stores. Only for the remaining parts that cannot be measured will a reason-based allocation be carried out. For instance, the monthly electricity consumption of the shared cold storage is 12,000 kWh at a blended rate of 0.80 per kWh, and the total cost is 9,600. If Store A has 40% of the refrigeration capacity, Store B has 35%, and Store C has 25%, then the allocated costs are 3,840, 3,360 and 2,400 respectively. The headquarters office uses 1,500 kWh of electricity; the proportion of floors used is 50%, 30% and 20% for each of the three stores, so the allocated amounts will be 600, 360 and 240. The landlord-billed common-area lighting is 600, allocated according to the floor area of 300, 180 and 120.
Compared with the single-base way, it can better adapt to all the cost pools by using the main driver, thus reducing cross-subsidisation for low-volume stores with high-volume ones. At the same time, it still leaves an audit trail; therefore, all bases of allocation need to be attached with capacity records, lease agreements and meter readings, and the proportion of allocation will be revised every year or whenever the store layout changes. By adhering to this method, the energy cost comparisons at the store level are fair, the performance of different outlets can be compared, and a stable basis is provided for the next variance analysis and cost-control suggestions.
2.4 Identification of Cost Anomalies and Inefficiencies in the Audit Process
The purpose of the analysis is to find problems and waste in the energy consumption of the utility, so the data of the energy consumption and bills can be sorted out. In terms of the chain of flower shops, the comparison in the first part is that we will compare the actual data of energy consumption and cost in different stores, equipment, or behaviour and so on to identify problems that have deviated significantly from the expected level. It is not to flag problems directly; rather, it is to differentiate between real waste and defects and explainable changes, thus making the reason for corrective recommendations clear and reasonable.
The basis of anomaly detection is the setting of standardised reference data. Since the scale, sales volume, and refrigeration capacity of chain stores vary, direct comparison of their absolute energy bills may be misleading. The auditor therefore determines three main indicators: energy cost per square metre of floor area at the building level; energy cost per dollar of sales to connect consumption with business activities; and energy cost per refrigerated case to study the performance of the most energy-consuming equipment in a flower shop. The above is an ordinary number; there will be a comparison of it among all outlets of different sizes, and then a relatively poor-performing one will be selected for focus.
Time-series trend analysis can be used for cross-sectional comparison. Monthly consumption is recorded for a minimum of twelve months to account for seasonality; thus, the consumption of floral refrigeration units increases in summer and during holidays. The pattern of a normal season should be similar in all years and for similar outlets. Deviations such as sudden changes in consumption that do not correspond to changes in the weather, opening hours or equipment show that there may be some problem with the refrigeration unit, such as a refrigerant leak, a broken door seal, etc., and thus, continuous operation of the compressor is required.
Threshold-based outlier detection is a method to determine the scale of outliers. After calculating the interquartile range or standard deviation of each benchmark in the chain, outlets that are more than two times the average consumption in the chain are selected as abnormal values. To meet the requirements of the threshold, each case in the flag will be reviewed before it is announced.
There are four typical types of anomalies that occur repeatedly in the audit of chain flower shops. First, billing errors will be checked by comparing the invoices with the meter readings and the utility contract and rate schedule. Second, faulty refrigeration equipment is checked by visual inspection; that is to say, one can measure the temperature in the refrigerator, observe how many times the compressor cycles are used, and check if the condenser is clean and the door is tightly closed. Third, after-hours waste, i.e., lighting, HVAC, or case lighting left on outside business hours, is verified using interval metering data, scheduled site inspections, or basic log sheets filled out by staff. Fourth, unexplained inter-store variance will be verified by ruling out structural reasons such as the age of the store, climate zone, and lease duration, and then carrying out comparative site walk-throughs between a high-cost outlet and a similar low-cost one to determine behavioural or maintenance differences.
To avoid false accusations and concentrate the funds of the rectification fund on actual poor operations at this time, rigorous verification is required to give proof for the cost-reduction measures in the audit report.
2.5 Case Application: Auditing Procedure in a Multi-Outlet Flower Shop Chain
In order to illustrate the application of the utility energy cost auditing process, we will discuss a fictional chain of flower shops with eight locations called Chain F in this section. Chain F has a flagship store of about 200 square meters, six other small neighbourhood stores (80 to 120 square meters each), and a small kiosk located at a transit station. Since cut flowers and potted plants need to be kept at a constant temperature and humidity, electricity is one of the main utility expenses in the whole network. The refrigerated display cabinets, air-conditioning units and other grow lights use about 85% of the total electricity, and the water used for irrigation is relatively small but essential for plants. The monthly electricity bill for the chain is 42,000 in local currency; due to differences in size, number of refrigerators and other reasons among the stores, there are also changes in the expenditure of different outlets.
Four steps will be taken in the audit. First, in the data collection stage, the auditors will collect twelve months of utility bills from all eight outlets and obtain sub-meter readings at the store level. Since only the flagship store has a separate sub-meter for refrigeration loads, the auditor will collect the equipment nameplate values, operating time, and the rate of turnover of products at each location in preparation for future calculation. In the second phase of normalisation, the raw consumption data will be modified by adding or subtracting weather effects based on the number of heating and cooling degree days and adjusting the number of people served by dividing the revenue by the area in square metres to make the comparison reasonable. Third, in the benchmarking stage, the normalised electricity cost per square metre of each outlet will be ranked against the median of the entire chain and in the interquartile range. Fourthly, in the anomaly investigation stage, the investigation on statistical outliers will be conducted based on the field interview and equipment inspection records.
The distribution and comparison results show that all the shops are close to the chain's middle of 38 units per square meter per month; only five of them deviate by less than 10%. However, Outlet 5, a normal neighborhood shop, has a refrigeration cost that is 62 percent higher than the median; the deviation in refrigeration cost is still the same among the four seasons and cannot be caused by weather. According to the site inspection, there are two reasons: the old display chiller's door gasket is damaged, and it has been operating for 20% longer daily cycles than similar equipment; another reason is that the scheduled defrost timer was set incorrectly to run four times a day instead of twice. The reason for the low cooling cost of the kiosk is not normal operation; it is due to a faulty sensor.
The results of the audit will result in tangible financial losses. The gaskets of Outlet 5 are to be replaced and the defrost timer will be reset; the monthly electricity bill is projected to be reduced by around 1,100 units, and the payback period for the investment of 5,200 units will be less than five months. Chain-wide application of timer adjustment and gasket upkeep plans for all refrigerators will help to reduce electricity use by about 18,000 units per year, equivalent to 3.6% of total electricity consumption. The case has proved that the systematic audit process can turn the raw billing data into useful, verifiable cost control measures that can be implemented in a large number of stores in a short time.
2.6 Improvement Recommendations for Energy Cost Control
Based on the audit results in the previous sections, this part will provide some suggestions for improving the energy cost control in chain flower shops. Each proposal is based on the identified problems and will provide an estimate of the cost savings that can be achieved to help the headquarters decide whether it is feasible and which one to implement first.
First, the audit found that refrigeration is the main reason for electricity use, but only a single main meter is used at present, so it cannot be separated to investigate the reason for abnormal consumption. Therefore, it is recommended that each store install its own sub-meter for refrigeration equipment. Sub-metering can monitor the refrigeration load on a daily basis, promptly discover problems such as leakage of the door seal or failure of the compressor, and accurately calculate the refrigeration cost per store. Experience from similar retail environments shows that the early detection of faults via sub-metering can reduce the waste of refrigeration electricity by 8 to 12 percent; hence, each store would save approximately 3 to 5 percent of its total electricity cost per month.
Second, there are two aspects that need to be upgraded. Energy-efficient display cases with good insulation and variable-frequency compressors can reduce the refrigeration energy consumption by about 20 to 30% compared to older units, and the payback period is usually within three to five years. At the same time, replacing traditional fluorescent lights with LEDs will reduce the lighting-related power consumption by more than half; since the lighting is in use all day during business hours, this alone can reduce the total power consumption by about 5 to 8 percent. The above upgrades will be implemented in stages, starting with the stores with the highest unit energy costs as identified in the audit.
Third, the existing cost allocation rules distribute the utility costs evenly among all stores according to their size or sales, thus reducing their sense of responsibility for cost control. It is suggested that the allocation be adjusted to a two-part system; that is, a fixed part based on the store's area and a variable part based on the actual metered consumption. This change will make store managers feel accountable for controlling controllable energy consumption and is expected to reduce overall consumption by about 3 to 5 percent through behavioural change alone.
Fourthly, headquarters shall set energy consumption indicators for electricity cost per unit area and per unit of sales, etc., and conduct internal audits on them on a regular basis, such as once every quarter. Benchmarking can quickly identify abnormal stores and spread good practices in the chain; usually, the savings are about five percent.
Fifthly, staff energy-saving training should be regularised and include how to operate refrigerators correctly, close doors on time and turn off unnecessary lights. Staff behaviour is directly related to daily consumption, and systematic training with a simple reward system can further reduce it by about 2-4%.
Finally, the headquarters should improve the uniformity of meter reading formats, recording times and reporting templates in all stores. Standardised data is the basis for benchmarking, auditing and performance evaluation; it was one of the main problems of this audit. In short, if the above recommendations are fully implemented, the cost of utilities for the chain will be reduced by 15%-20% in the first year of operation.
Chapter 3 Conclusion
We will now conduct a generalised energy audit of the utility expenses for the above chain flower shop, and explore the whole process from preparation to the collection of data in the workplace, followed by analysis and reporting. The results show that the small retail companies will be able to identify the abnormal consumption of electricity and reduce some of the unnecessary consumption by applying the same audit to many stores [6].
The fundamental purpose of the audit is to make the utility cost comparable, and thus its meaning can be realised only in relation to the company's other operating indicators, such as floor space, refrigeration hours, changes in demand according to seasons, sales volume, etc. Normalisation is carried out for electricity and water used per unit of production in order to distinguish the fixed costs of the company's production model from the controllable losses caused by equipment ageing, waste, or incorrect tariff setting. This distinction is significant, as the two types of reduction are quite different.
From an operational point of view, it can be seen that the data integrity in the audit is the key to good results. The electricity bills need to be checked against the sub-meter readings and the operation schedules; otherwise, it will lead to problems such as incorrect charging, extra power consumption that is not approved, and faulty meters, etc., and all of these will be compensated by the electricity company. Cross-store benchmarking has been used in the studied chain to show the various characteristics of all the shops; therefore, a single-store audit cannot reveal the problems at the site [3].
The practical use of this study is to show that the energy audit can be applied to small-scale industrial enterprises. For the small and distributed retail stores, a concise yet systematic auditing system (such as consistent data templates, uniform measurement intervals, etc.) will be used to obtain relatively low-cost and effective results. The recommended implementation plan is to first collect all the old bills, measure the energy consumption at a representative time, and finally offer targeted and cost-effective suggestions for management to order the repairs in terms of payback time.
There are some shortcomings that need to be pointed out. The data for the audit only cover part of the seasonal fluctuations in consumption; thus, conclusions cannot be drawn about high-season consumption. Refrigeration equipment is the main load in flower shops, so it should be monitored for a longer time to distinguish the impact of the weather from the decline in equipment performance. In addition, the behaviour of staff opening the door and the use of lighting were monitored qualitatively rather than quantitatively; it is therefore suggested that staff training evaluation and low-cost sub-metering be added to the work to strengthen the basis of evidence in the future.
Finally, the utility energy cost audit can provide a relatively stable way to manage utility payments for chain flower shops. If it can be incorporated into the daily operation of stores through regular audits, updated bases of comparison, and clear responsibilities for energy consumption, it will help reduce costs continuously, extend the life of equipment by detecting faults early, and help achieve the goal of saving resources on a larger scale. The standardised procedures that will be put forward in this paper are given to help similar small-chain retail enterprises carry out professional energy cost management without investing a large amount of money.
References
[1]Dnyaneshwar S. Raut, Yogesh Borole, Lalit Kumar. Energy Audit[J]. Multidisciplinary Journal of Research in Engineering and Technology, 2025.
[2]USDOE Office of Energy Efficiency and Renewable Energy (EERE), Energy Efficiency Office. Building Technologies Office, Michael Baechler, Cindy Strecker. A Guide to Energy Audits[J]. 2011.
[3]Ali Hasanbeigi, Lynn Price. Industrial Energy Audit Guidebook: Guidelines for Conducting an Energy Audit in Industrial Facilities[J]. 2010.
[4]Albert Thumann, Terry Niehus, William J. Younger. Handbook of Energy Audits[J]. River Publishers eBooks, 2003.
[5]Uchkun Mirzaev, Davirov Ashraf, Abirov Akbarbek. Energy Audit Basics, Energy Audit Tasks And Energy Audit Methods. SSRN Electronic Journal, 2021.
[6]Barney L. Capehart, Mark B. Spiller, Scott Frazier. Energy Auditing[J]. River Publishers eBooks, 2020.