1.1 Research Background

With the rapid development of intelligent parking management systems, more and more urban communities and commercial complexes are building underground parking lots with an automatic navigation system. A distributed routing node is employed in this system to enable real-time vehicle positioning, trajectory calculation, and dynamic space distribution. Nevertheless, some problems have appeared in the application of such architectures in practice due to environmental and operating pressure. Subterranean facilities are mostly dense, reinforced concrete structures; hence, they will regularly attenuate and often block short-range wireless communication signals, leading to significant transmission delays and frequent disconnections of routing nodes. In addition, the operating mode of such intelligent garages will have a lot of changes in the morning and evening rush hours of daily life; during this time, there will be many cars entering, resulting in a large number of navigation requests and thus, the network will be too busy and the system will collapse. The problem of structural signal occlusion and bursty communication loads has brought about a crucial flaw in the current routing architecture: insufficient fault tolerance in the event of extreme loads. If the routing architecture does not have good fault tolerance, the cascading failure of the surrounding nodes will spread to all parts of the network and cause the system to stop functioning. Such architectural faults are manifested as severe vehicle congestion at the entry and exit gates, disabled automatic guidance, and a decline in user experience. Therefore, the problem of reliability in an underground garage's routing system when it is disturbed or saturated is an important issue. To systematically quantify and address the above potential systemic risks, there is an urgent need to conduct some relevant pressure tests in practice. Simulate extreme working modes and intentional node failure injections in stress testing to obtain empirical data for verifying the fault tolerance of routing networks, discovering topological problems, and gradually improving the resilience of the system to ensure continuous and stable operation of the garage under adverse environmental and computational conditions.

1.2 Research Objectives and Significance

The main purpose of this paper is to design a stress-testing system based on the actual situation of an underground parking garage, so as to find out the tolerance limits of each routing node under large loads and all kinds of interference. In the underground environment, there is a lack of space for radio signal propagation in the closed areas of vehicles, buildings, etc., and it is often subjected to multipath fading and many other problems. The traditional general stress testing model cannot simulate the above-mentioned various forms of physical disturbances well, so it cannot meet the demand for targeted performance verification of short-range wireless routing nodes in closed underground spaces. In theory, this paper will address the deficiencies in this area by developing a generalised testing method that can determine the basic working range and resilience of various routing protocols under different types of environmental changes. Based on the formal definition of the degradation trajectory of routing nodes from the normal state to the critical failure threshold, this study provides a firm mathematical and empirical basis for studying the law of fault tolerance in small-scale space-electromagnetic environments.
From a practical application perspective, the research results are relevant to support the stable operation of an intelligent vehicle navigation system, an automatic parking system and a garage management system. These applications need to keep sending data continuously for real-time monitoring and control of the vehicle; otherwise, there is a high possibility of sudden failure or a large number of problems. At the same time, the experimental results of the stress testing system are very helpful for optimising the deployment location of the routing nodes. Based on the above research results, underground garage operators and system integrators can know the exact failure threshold under various disturbances, thus formulating an appropriate redundancy plan and reasonably distributing the network topology. Therefore, it can save costs for the construction of infrastructure, meet industry reliability standards and finally ensure the steady operation of communication required by automated underground mobility systems.

1.3 Domestic and Overseas Research Status Review

This paper will discuss the systematic review of relevant disciplines for the research on fault-tolerant routing nodes in underground garages: general wireless routing node stress testing, performance verification of indoor positioning and navigation networks, reliability of underground space communication networks, and design of fault-tolerant mechanisms for Internet of Things (IoT) nodes. Foreign scholars have established a sound system for general wireless stress tests that are mainly concerned with throughput and packet loss in the ideal environment of open space or controlled conditions. At the same time, some advances have been made in the verification of indoor navigation networks in China, but these have mostly assumed that the anchor node is always stable. Existing studies on underground space communication have detailed the signal attenuation and multipath effects caused by structural obstruction, but they have been in the majority studying the reliability of fixed links rather than the resilience of dynamic routing. Additionally, although there are some studies on fault-tolerant mechanisms for the Internet of Things (IoT), such as cluster-based recovery and redundant path routing, they are usually optimised for open or semi-open environments with relatively high access density.
Through a comparative analysis, it is found that applying the above-mentioned results to the particular case of underground parking lots will be insufficient. General stress testing models are not targeted for simulating severe signal occlusion in the environment; indoor navigation verification does not consider anchor node failure due to high-density concurrent access; current studies on underground communication do not consider the dynamic topology change caused by vehicles. Therefore, there is currently a large gap in the research; few have studied how fault tolerance of routing nodes behaves under the combined conditions of blocked signals, high-density concurrent access, and dynamic topology changes. This combination has changed the way traditional fault recovery works, making the old redundant routing protocol no longer suitable due to a shortage of local resources and rapid changes in the network's structure. Based on the above limitations, this paper will start from these problems and put forward a new idea: to develop a special test method for fault tolerance stress that can comprehensively evaluate the resilience of routing in the combination of extreme conditions in underground garages.

1.4 Research Scope and Overall Technical Route of the Paper

The scope of this paper will be only for the fault-tolerance performance stress test of dedicated short-range wireless routing nodes for intelligent underground garages. Therefore, we will not conduct a performance test of the long-distance outdoor communication base station and general routing equipment that do not meet the above conditions; otherwise, some new interference and topological problems caused by the electromagnetic propagation characteristics, space-limiting effect, and mobility characteristics of the underground parking environment will be overlooked. Through the above restrictions, the study can provide some basis for the improvement of local vehicle communication networks.
The overall technical route of the research is divided into five modules. To begin with, a basic theoretical background for routing protocols and fault-tolerance mechanisms in wireless sensor networks with a limited space will be presented. The first module is to determine the main indicators and restrictions that the node reliability should meet. Second, based on this theoretical model, the weaknesses of the existing scheme will be analysed to reveal the drawbacks of the current fault-tolerance scheme in high-density, high-interference underground environments. Third, a targeted testing system will be developed to quantitatively test the stress resistance of routing nodes in extreme conditions by employing topology simulation and fault injection. The core problem of this paper is to realise controllable and repeatable stress scenarios that can truly reflect extreme operating conditions. Fourth, the reasons for the change in the state of the node and the corresponding packet loss and rerouting delay will be analysed to determine how far the node fault-tolerance can be applied in practice. Finally, according to the empirical results, some suggestions to improve the resilience and load balance of the network will be put forward.
There is a strict sequence and iteration among these modules; that is, theoretical guidance is used to identify the deficiencies, and then a test plan is worked out; experimental practice will be carried out according to the design and the results of practice will be used to formulate an optimisation plan. The above arrangement can conduct a full range of research from the theory of abstraction to the problem of practical improvement of underground routing fault tolerance.

Chapter 2 Core Concept Definition and Theoretical Foundation

2.1 Core Concept Connotation Clarification

2.1.1 Underground garage routing node and its operation mechanism

The routing node of underground garages is a special wireless communication device that is deployed in closed underground garages to transmit positioning signals for vehicles, send navigation instructions, collect data on the state of vehicles, and so on, and to be connected to the upper-level Garage Management Platform. Different from general home or office routing nodes that are built for high-throughput fixed connection in relatively open electromagnetic environments, the underground garage routing node will be in a relatively bad communication channel. The operation mechanism of the company should be able to handle the complicated signal reflection and shielding conditions of reinforced concrete structures; otherwise, serious multipath fading and non-line-of-sight propagation will occur, thereby reducing the accuracy of the data. There are frequent changes in the operation mode of the node, and the connection objects will also be changed accordingly. It should quickly switch between the stable links of the moving vehicles and the fixed sensing devices in the garage, and it can still work properly even with the constantly changing topology. At the same time, the system is subject to an extremely low delay requirement to complete data forwarding, so it can deliver navigation instructions and real-time position timestamps without delay, which is necessary for collision avoidance and smooth traffic. Different from the traditional nodes that have a fixed routing table and can tolerate some delay in transmission, the underground garage routing node needs an adaptive routing algorithm and timely link quality monitoring to predict and solve temporary signal blockages. This kind of operation mode combines strong anti-fading transmission with fast connection handover and deterministic low-delay forwarding to ensure the reliability of vehicle-to-everything communication and the stability of intelligent transportation in the underground garage. Therefore, only by grasping the particular meaning and operation details of this type can we design an appropriate fault tolerance and high-stress test case for it; otherwise, any sudden routing failure or delay in such a small and dynamic environment will affect the normal function and safety of the system.

2.1.2 Fault tolerance performance of routing nodes under high load scenarios

The fault-tolerant performance of routing nodes in heavy-load situations is that the nodes can keep providing services steadily, without unplanned downtime, forward data packets correctly and still be able to communicate normally in the case of severe circumstances. Usually, these are some extreme situations, such as too many access devices, too much data transmission, part of the hardware or software malfunctioning at the same time. The above are general reasons, and in the actual situation of an underground garage with limited space and poor signal, the transmission of data in a wireless network will face more difficulties; thus, this type of fault is not just an extra function but also quite reliable. To avoid cascading failures and resource depletion in the routing infrastructure due to a large number of concurrent vehicle authentication requests and continuous navigation data streams.
Based on the above three main functions, we will now discuss the specific performance indicators in detail. In the first place, no packets should be lost in the important navigation data. Routing nodes need to set up high-QoS and queuing rules to ensure that time-sensitive routing commands and spatial coordinates are delivered reliably when there is a large amount of traffic at the entrance; otherwise, the number of packets would be too high and exceed normal limits. Second, the system should guarantee that there will be no invalid disconnection of connected vehicle terminals. At this time, a long-lived session and a stable link must be maintained to prevent the routing node from dropping connections due to buffer overflows and memory shortages in high-traffic periods. Third, the system should be able to recover automatically from faults within a short time. Therefore, a local self-healing scheme will be introduced in terms of the hard fault self-healing method and the soft fault self-healing method to enable autonomous detection, isolation and restoration of faults or abnormal operation of the node without human intervention; at the same time, the average time for system recovery will be set appropriately. These two aspects constitute the theoretical basis of the evaluation model for routing resilience and are the first line of support for the next step in researching how to test the upper operational limit of underground garage network infrastructures.

2.1.3 Stress testing framework for node performance verification

The stress testing framework for node performance verification is a standardised system for testing the different types of high-load and abnormal disturbances that routing nodes might experience in an underground garage. Its basic idea is to create controllable, adjustable load pressure; collect real-time operation data of nodes; and quantitatively assess the fault tolerance of the nodes. Routing nodes will have to deal with many things in the underground garage's highly complex environment and dense traffic, such as a sudden increase in traffic, signal loss, and packet loss. Therefore, this framework will have a strict closed-loop experiment model to test whether the nodes will be stable in routing and forwarding data even under some unusual circumstances. Four modules are in this framework and work together. To establish a high-fidelity environment close to the actual operation of an underground garage, a digital twin is created that can simulate the spatial structure, communication channel conditions, and movement of vehicles in the parking area. The load generation module will serve as a tool for generating network traffic and computational demands at various times, simulate the situation of peak hours and sudden surges, etc., and then determine how severely the node's throughput and latency will be affected. The fault injection module will continuously introduce faults such as link failures, memory overflows, and hardware clock desynchronization into the node's operation, so as to investigate how robust and far-reaching the fault tolerance mechanism of the node is and whether it can switch to other paths to avoid interruption or exceptions. Finally, the data analysis module will gather all kinds of data related to the operation of the nodes and use various indicators to determine how well the nodes handle problems and recover from them. Through the coordination of these modules, the framework converts the qualitative fault-tolerant phenomenon into a quantitative one and establishes a solid scientific basis to improve the reliability of the routing system for underground garages.

2.2 Key Theoretical Basis for the Study

2.2.1 Dynamic topology matching theory for indoor short-range wireless routing

Dynamic topology matching theory is a new theory that addresses the problem of how network connections in short-range wireless routing change over time due to the dynamic nature of the environment. The network topology of the garage's routing nodes is not fixed; rather, it is adjusted according to various physical changes around us in real-time. A large number of vehicle-mounted access terminals are constantly moving, so the communication links and routing routes will also change with them. When the garage fence is opened or closed, obstacles that are constantly moving in and out can change the propagation path of the signal and cause multipath fading and shadowing. Therefore, the wireless routing structure is changing all the time, and a fast-converging routing protocol is required to ensure that the network can be reached at any time.
In the stress testing of the fault tolerance of the underground garage routing nodes, a new way to create dynamic load scenarios has been developed based on this theory. The old method of testing with a fixed topology cannot reflect the random volatility of real life, and thus the result of fault tolerance will be too optimistic or biased. Based on the theory of dynamic topology matching, in the simulation environment, the change of topology due to the movement of vehicles, the blockage of links by barriers, and the attenuation of signals by gates will be introduced. Therefore, the dynamic load scenarios in the simulation will be close to the actual operating state in terms of time and space.
Finally, the fixed topology cannot fully capture the changes in the system caused by stress testing; therefore, this theory can help us find them. The stress testing engine will evaluate the fault tolerance of the routing node in a changing environment, and the test results will be generalisable to other underground garages that are not very stable due to their topological structure. According to the empirical laws of operation, the validity and reliability of the fault tolerance evaluation will be guaranteed.

2.2.2 Node fault tolerance response model under high-density user access

The node fault-tolerant response model in the high-density user access environment is an important theoretical basis for studying the resilience of the underground garage routing network. When the number of access vehicle-mounted terminals in a local area suddenly increases to more than 100, the spatial density of concurrent connection requests will have a large number of dimensions to stress the routing nodes. Based on the above model, it is known that the change law of node resource occupation shows an unsteady and sudden increase. Specifically, CPU usage will increase linearly to exponentially in the later stage due to increased overhead from context switching and routing table lookups. At the same time, the number of concurrent buffer queues used to receive new terminal sessions on the node will be too large, so the memory occupancy rate will increase sharply. At the same time, the wireless channel bandwidth will also be close to saturation due to high medium contention and a sharp rise in collision probability during channel access.
When the total resource demand exceeds the node's inherent fault tolerance threshold, the internal mechanism will start a series of declines in communication quality. Response delay is mainly due to the overflow of the processing queue, and packets will be queued for a long time because the CPU has been scheduled for too long and there is not enough memory buffer. Packet loss occurs when the network interface card of the node and the routing protocol stack are no longer able to enqueue incoming data packets; otherwise, the buffer will drop them due to insufficient memory. In addition, at the data link layer, bandwidth saturation will lead to continuous transmission failure and retransmission timeouts. Disconnection is the final type of failure; at this time, due to serious response delays, the keep-alive mechanism has timed out, or the routing daemon has crashed due to excessive memory allocation errors and thus lost the connection between the vehicle-mounted terminal and the network infrastructure. To explain this fault-tolerant response model, we need a theoretical basis for the subsequent construction of a stress test index system; that is, resource occupation limits and degradation mechanisms will be directly mapped to measurable test indicators, and a strict procedure will be provided for performing targeted fault injection and load saturation tests.

2.2.3 Load boundary calculation principle for underground garage routing systems

Load boundary calculation theory of underground garage routing system is the foundation for scientific stress tests. The main issue is how to determine the maximum load limit of a routing node cluster under the specific circumstances of the garage environment, such as the structure and operation of the garage. The upper limit of the routing load is not a variable that can be expanded endlessly; it is determined by the actual area of the garage, the total number of parking spaces, and the maximum capacity of vehicles that can be accommodated in the available space. Based on the usual peak flow law (Short-term surge occurs during commuting hours), the theoretical maximum load limit is expressed as the product of the maximum concurrent vehicle density in the physical space topology and the peak request generation rate per vehicle.
This is the theoretical basis for deriving the reasonable range of gradient load values in the stress test. Set the upper limit of the absolute load based on the above constraints, then divide the gradient test interval. This deduction process generally maps the continuous operation flow function from the baseline state to the calculated theoretical boundary after gradually increasing the load. It should be noted that this principle will not lead to an excessive load in the test, as in reality, the load is limited. The fault-tolerant data obtained by injecting an overload beyond the physical access capacity or space saturation will not be useful in actual life and will be excluded from the stress test. Therefore, to keep the load boundaries in the test within the range of the actual operation of the underground garage, the test's load boundaries must be strictly limited; otherwise, the failure tolerance and system degradation behaviours of the routing nodes in the test will not reflect their true operational conditions but will be artificially created due to an unrealistic overload.

2.3 Current Common Deficiencies of Existing Testing Schemes

2.3.1 Limitations of traditional routing node performance testing in closed space scenarios

The usual way to test the performance of a routing node is by using an empirical model and a testbed built for an open or semi-open indoor environment. However, underground garages belong to a relatively closed space, and thus the structure is not simple; therefore, the basic ideas of the traditional test method do not apply here. In addition, there are many reinforced concrete structures in underground facilities that will lead to a great deal of non-linear signal attenuation and multiple paths. The ordinary plan is to use free-space path loss or general indoor propagation models; the above are relatively small, and do not consider the effects of dense mineral matrices on absorption and scattering. Therefore, the theoretical basis constructed by these traditional tests differs somewhat from the true characteristics of electromagnetic waves in limited underground areas.
The other reason is that the operation of an underground garage will generate widespread interference to signals because many large metal objects are moving vehicles and structural columns. High-conductivity objects can be used as reflective and diffractive surfaces; thus, there will be irregular fading channels and transient shadow zones. The standard way to conduct the tests has not been adjusted to take into account the random changes in space and time caused by this sort of metal grouping. Often, it is considered that the environmental interference is a static attenuation factor, or a random additive white Gaussian noise; the actual underground traffic flow has a dynamic geometry-dependent scattering effect, and thus these effects cannot be ignored.
Thus, the performance metrics obtained by the traditional test methods are too ideal. Due to the lack of consideration of the combined effects of structural signal attenuation, complicated multipath propagation and metal interference, the performance of the traditional test will be too high and unreasonable in terms of packet delivery rate and routing stability index. Therefore, the old kind of test cannot fully verify the fault tolerance and stress resistance of the routing node for use in the underground environment. Without a method of testing that is close to a closed-space scene, the obtained performance parameters cannot be used to reflect the actual operation of a node, and thus, they are not reliable for the underground garage routing network under stress.

2.3.2 Gap between existing stress testing parameters and actual operation requirements of underground garages

The basic flaw of the current stress-testing schemes is that the parameters are far from the actual operation demand of the underground garage's routing nodes. The mainstream way now is to use a standard office network access for the parameters. This mode is suitable for the measurement of the switchgear of a normal enterprise, but it does not reflect the complexity and dynamism of the network in a car environment. Generally, the test parameters are usually based on the static throughput and average delay of a stable connection, and fail to consider the special parameters of underground garage operation.
To begin with, with the change in the routing coverage area of the garage, there will be frequent switching of the vehicle terminal access point in this case. The current test schemes generally do not take high-frequency roaming handover indicators into account, nor do they consider the change in packet loss during short-term connection re-establishment. Second, the underground navigation is mainly to meet the priority transmission of navigation emergency data, such as obstacles and rerouting. Conventional stress tests tend to treat all data packets equally and do not have mechanisms to simulate priority preemption or test the performance of routing nodes under different Quality of Service constraints. Thirdly, a large number of vehicles are travelling in and out at the same time, resulting in an increase in positioning data. Standard benchmarks are usually gradual or linear load increases that cannot reflect the bursty and unicast-to-multicast traffic at peak times in the garage.
Therefore, the fault tolerance performance indicators obtained from tests with too few parameters may not accurately represent the actual operating conditions of the nodes in an underground garage. The problem is that the office-network model assumes good performance, but the actual environment of the car may cause packet loss, handover failure, and other problems in the office-network model. Therefore, it is necessary to address the parameter gap and improve the accuracy of fault tolerance evaluation to guarantee the reliable operation of the underground garage's routing infrastructure.

Chapter 3 Design of Underground Garage Routing Node Fault Tolerance Stress Testing System

3.1 Overall Architecture Design of the Stress Testing Platform

3.1.1 Simulated underground garage operation environment construction module

Simulation underground garage operation environment construction module, as the basic infrastructure of stress test platform, can simulate the complicated physical and electromagnetic features of real-life underground parking lots. The basic idea is to set up a hardware and software co-simulation environment that is highly consistent with the physical environment and signal transmission rules of a real underground garage, thus ensuring that the subsequent fault-tolerant stress test of the routing node has been carried out under an ecological environment. For this reason, in the module, the signal attenuation device will be added to simulate the signal attenuation caused by different materials in an underground garage, such as reinforced concrete, metal pipes, partition walls, etc. Configure a variable attenuator and change the path loss model based on the permittivity and conductivity of the material to accurately imitate the non-linear attenuation of communication signals at different obstacles for the platform.
The module will be able to mimic the mobility of high-density parking scenarios with a mobile signal source that can be programmed. The software defines a path and speed for these sources, so that many car movements can be simulated. By changing the positions and transmission characteristics of mobile sources all the time, it can simulate the time-varying network topology and transient communication load of vehicle nodes, which are necessary to assess the stability of routing protocols under dynamic stress.
Reproduce the multipath effect and signal reflection scenes that are typical of closed garages. The confined architecture of the underground garage will inevitably lead to serious multipath propagation; that is to say, when transmitting signals, they will be reflected by walls, ceilings and metallic vehicles and then reach the receiving antenna with different phase shifts and delays. A programmable fading emulator and a spatial reflector array are used to build the co-simulation environment of the module and simulate the multipath interference and reflection of the wireless signal. Based on the precise synchronisation of hardware-in-the-loop signal processing and software-based ray-tracing algorithms, this module can be used to build a controllable, high-fidelity electromagnetic test bed. Strict environmental fidelity is required for isolating and analysing the resilience and degradation thresholds of routing nodes under the combination of signal interference and topology in the stress test.

3.1.2 Multi-dimensional fault injection component for routing nodes

A significant part of the multi-dimensional fault injection module is in the architecture of the stress-testing platform; therefore, it is built to simulate all kinds of complex and varied abnormal conditions that may occur in underground garages. A basic definition of a fault injection model is that it should be able to simulate various kinds of controllable faults to be injected at the target routing nodes and to separate and judge the fault-tolerance response of the routing system under these predetermined disturbances. To simulate various actual operation failures in an all-round way, this component will have five types of faults: node hardware overheating, leading to heat throttling or sudden failure due to continuous operation; local network port malfunction due to data transmission problems; software process crash caused by memory overflow of the routing firmware; adjacent node signal interference caused by wireless transmission in a crowded underground area; partial power supply fluctuation caused by unstable power supply that affects the stability of hardware.
It has been discovered that the main reason for the failure of this part is that there is no proper control of three basic parameters: when to inject the fault, how long to keep the fault going, and how severe the fault is. Based on the timing of injection, the platform will be able to choose different periods for the faults according to the operation of the system or traffic. The fault duration is used to distinguish between a temporary glitch and a persistent failure. To improve the fault-tolerant degree of control, the performance gradually worsens until it is no longer able to function properly. Through the three parameters, one can generate different and adjustable test conditions. Therefore, researchers can systematically cover all failure modes and establish a new, empirical path to verify and quantify the fault-tolerance response of underground garage routing nodes; finally, they can guarantee the system reliability and robustness that need to be provided by important vehicle navigation facilities.

3.1.3 Real-time performance data acquisition and analysis subsystem

The real-time performance data collection and analysis subsystem is the basis for the stress test platform; it has been built from basic modules to receive, process and analyse real-time operation conditions of routing nodes under fault-tolerant load. The main function of the design is to collect all the important operation data of the underground garage routing node under test in the stress test at the same time and require millisecond-level time accuracy. Since transient anomalies in routing nodes are often observed within a short period of time, and a high-resolution timestamp can help us capture all the critical changes of a system, it is necessary to have such data. Specifically, the collected metrics are: CPU and memory usage, packet forwarding success rate, access terminal response time, network reconnection time after abnormal conditions, and channel occupation ratio. These indicators show various problems of the routing node in terms of computing resources, data transmission, service continuity and network bandwidth when it is affected by faults.
After being collected, the subsystem will automatically organise the raw data from the telemetry into a structured Analysis Asset. Automatically compare real-time indicator values with a set threshold and sort anomalies by degree and time. Automatic processing reduces manual analysis and improves the objectivity of fault assessment. At the same time, the subsystem will visualise the changes in each performance metric with time-series graphs and scatter diagrams as stress levels and faults are introduced. Through simple visualisation of the transient spike in the delay of the access terminal and the change in reconnection time after a network failure, it will directly help identify systemic problems and vulnerability points. Finally, this comprehensive acquisition, automatic comparison, sorting, and visualisation pipeline can provide the necessary data support for the subsequent quantitative analysis of fault-tolerant performance, so that the evaluation of the underground garage routing system can be based on solid empirical evidence.

3.2 Determination of Stress Testing Index System

3.2.1 Basic load resistance indexes of routing nodes

The first two lists of the routing node are the first standards to judge whether the routing infrastructure can withstand some form of failure or abnormal disturbance, as well as what it can naturally handle. The specific underground garage signal environment is harsh due to multipath fading, low signal strength, and numerous electric disturbances; therefore, the construction of these indicators must be based on the physical transmission rules of this area. The first index is the maximum number of stable access terminals; that is to say, the routing node can bear the maximum number of concurrent vehicle-mounted or pedestrian mobile terminals in the case of an abnormal operating state, such as a drop in connection or a timeout, without affecting the underground garage signal propagation model. At the same time, the maximum data packet forwarding rate per second is used to measure the node's data plane throughput, which is the peak value of payload processing and routing operation rates under normal protocol overhead. In addition, the maximum allowable load at which there will be no continuous packet loss is important for determining the quality of service; it is the exact moment that buffer overflow changes from transient drop tolerance to a long-term and continuous packet loss, indicating the limit of stable queue management. Finally, we will display the resource utilisation rate of each core component under various load gradients. To systematically apply an increasing traffic load stimulus and track the changes in the CPU, memory, and NIC utilisation of the central processing unit over time. The above gradient analysis can show how long the node's linear and non-linear resources will be used up in order to obtain the maximum load level. All these indicators can accurately measure the basic load-bearing capacity of the routing node under normal operation, and they are necessary for calibrating the subsequent fault tolerance stress test and accurately determining the degree of performance degradation caused by the simulation of node failure.

3.2.2 Fault tolerance performance indexes under abnormal disturbance

Underground garage routing node fault tolerance stress testing can determine the performance indicators in abnormal disturbances, and then calculate the inherent robustness of the node itself quantitatively. The basic definitions of these indexes are based on how well the system can recover from sudden changes in hardware or software. The main idea is to set a strict, quantitative line of demarcation for acceptable degraded operation and catastrophic failure. Among these indicators, the data packet loss rate of key services when there is a single or multiple accidental faults is the first indicator of service continuity, directly reflecting whether the routing node can maintain data stream integrity in the event of topological instability. The time taken by the node to automatically restore normal operation mode after a fault occurs is considered as the self-healing efficiency, which is necessary to restore good traffic flow routing without any manual intervention. In complex underground environments, the misforwarding probability of navigation data packets under conditions of high load and faults is one of the parameters used to assess how well the routing algorithm can perceive the environment; it reveals that resource contention and concurrent disturbances might result in errors in vehicle guidance. Moreover, the maximum allowable fault severity that the node can bear without being forced to restart is defined as the structural threshold of fault absorption, showing the ability of the system to withstand partial damage or resource depletion and maintain state persistence. Finally, the integrity rate of stored operation log data when an abnormality occurs is required for post-mortem analysis and system audit to ensure that the diagnosis and forensic information are not lost due to the disturbance. In practice, these indexes will form a whole assessment system together. By systematically applying abnormal disturbances and monitoring these specific indicators, researchers can accurately identify the weak spots, verify the effectiveness of redundancy mechanisms, and ensure that the underground garage routing infrastructure meets the required reliability and safety standards according to industry regulations.

3.2.3 Multi-node collaborative response efficiency indexes under extreme stress

To determine the multi-node cooperative response efficiency index under extreme stress in the underground garage routing node fault-tolerant stress test system, one must first know how well the whole network can work at its full capacity. The above indexes can be used to measure the effect of routing node clusters in a high-load operating environment on load balancing and recovery. The first important index is the data transmission delay among nearby Routing nodes when the network is operating at peak load. The amount of marginal latency due to channel congestion and computational bottlenecks is determined by how much extra delay is added; it basically shows how efficiently communication between nodes can function at maximum throughput. The second index is the success rate of seamless handover of the vehicle-mounted terminal from a faulty node to a normal adjacent node. It can be seen that there is a high probability that a client connection will be lost during a topology change, and this needs to be addressed to ensure continuous navigation service. The third index is the total duration of service interruption in the local area after one node fails. The length of time when no routing service is provided due to a single node failing can be used to measure the speed of collaborative fault detection and bypass path activation for clusters. The fourth index is the load average distribution efficiency of the node cluster when some nodes are overloaded. It is to check whether dynamic load-balancing algorithms are effective in redistributing the excess traffic of the failing node to other nodes, thereby avoiding cascading failures caused by lack of resources in one place. Together, the above four indexes form a strict evaluation system. They can be used to evaluate the overall fault tolerance performance of a Routing node cluster in an actual underground garage networking environment and ensure that stress testing can correctly reflect the resilience and collaborative stability needed in practical operation.

3.3 Optimization of Stress Testing Execution Process

3.3.1 Step-by-step load gradient increase strategy

In the underground garage route node fault tolerance stress test, the way to increase the load in steps is to change the way the system operates so that it can be properly assessed under different levels of traffic. The core idea of this plan is not to apply extreme sudden high loads, but rather to gradually increase them in a controlled manner, and thus observe the changes in performance over time rather than just when there is a sudden failure. First, the minimum base load is set at 10% of the usual peak traffic in the underground garage. Based on this initial condition, the load can be gradually increased by a fixed 10% each time. At each time of the new gradient, the system will be kept in the same load condition for at least 15 minutes. In other words, it takes some time for the queue to be emptied, for the routing table to be updated, and for memory to be freed in the routing node; otherwise, transient changes will not be a good indicator of the real problem. This gradient plan has great practical value. If the full load test is done at once, it will fail immediately, and we will not be able to detect the real sudden change in the performance of the node. With the gradual increase in stress, this method can be used to continuously monitor the changes in some important indicators, such as the packet loss rate and routing recovery delay, and thus determine the critical load threshold at which the fault tolerance performance of the routing node starts to decline. Therefore, this method can be used to alleviate the sudden shortage of resources and provide empirical data to determine the exact operating limits and the process of reduced fault tolerance for the routing node in an underground garage environment.

3.3.2 Controlled fault scenario triggering and reset mechanism

During the operation of the fault-tolerant stress test system for the underground garage routing nodes, a Fault Tolerance stress test is conducted to trigger and reset the faulty nodes. Basically, it is to inject and then remove some anomalies in the routing topology in a certain way, and thus the testing mode will be changed from random simulation to deterministic verification. The main idea is to synchronise the observed load state of the target node with the specific fault vectors set in the test by using a time-based and condition-controlled logic. The mechanism will select the time when the test fault will be injected based on the given test plan. Moreover, when the operating load of the tested routing node reaches a certain value, it can automatically trigger the preset combined fault of node communication timeout and packet loss. When the set Fault is over, the mechanism will carry out an automatic reset; it will cancel the injected disturbances and return the node to its normal operating status. This kind of cyclical trigger and reset way is necessary in practical applications to make the whole test process controllable and all the Fault Scenarios be completely reproducible in different tests. To maintain a stable environment for the test, it is necessary to avoid the interference of people's mistakes on the test results; otherwise, it will be difficult to determine the fault resistance of the underground garage routing algorithm. Therefore, a good degree of experimental accuracy is obtained in this way; thus, a quantitative analysis of the fault-tolerance performance of the routing protocol can be carried out without being affected by the extra factors due to manual intervention or changes in environmental conditions.

3.3.3 Benchmark group and verification group setting scheme

For the test to have scientific validity and objectivity, it is necessary to set up a baseline group and a verification group in the Underground Garage Routing Node Fault Tolerance Stress Test System. The benchmark group is a test group in a traditional testing environment that does not include an underground garage scene and does not add any faults. To determine the normal behaviour of the routing nodes in an ideal, unobstructed and fault-free environment. The verification group is the test group, in which the underground garage environment is simulated and the execution process of the stress test is optimised; therefore, it is set to increase the load gradually and inject faults in a systematic way. Through this kind of arrangement, it is possible to observe and measure the behavioural pattern and stability boundary of the routing nodes when facing different stressors due to the complex spatial signal attenuation and specific node failures in underground scenarios.
In order to ensure that the results of the experiments are comparable, the benchmark group and verification group will use the same batch of routing node hardware and run the same version of software. By strictly controlling the hardware and software, it is possible to eliminate the influence of other factors such as differences in manufacturing, firmware and computing power on the results of the experiment; thus, any change in output indicators will only be caused by changes in environmental and fault conditions. Therefore, by comparing the test data of the two groups, we can clearly see the performance difference of the nodes under different test conditions. The benchmark group is a reference for the absolute performance of a node, and the verification group is to show how well it can withstand failure in reality and under extreme conditions. Based on this scheme, not only can the performance degradation rate and resilience threshold of the routing nodes be quantified, but also the efficiency of the improved stress test execution process can be verified through experiments, thus providing strong evidence for the reliability assessment of routing systems in underground garages.

Chapter 4 Experimental Verification and Result Analysis of Fault Tolerance Stress Testing

4.1 Experimental Environment Configuration and Test Sample Selection

4.1.1 Hardware and software parameter configuration of the testing platform

The first is to set the parameters of hardware and software to provide a reliable basis for the subsequent tests of reliability and validity under fault-tolerant stress. The main components of the test platform are the simulated load generation server, signal attenuation module, fault injection device and data acquisition and analysis sub-system. A high-performance computing node with two Intel Xeon Gold 6248R CPUs and 256GB DDR4 ECC RAM has been chosen as the load generation server; it will be used to simulate numerous concurrent routing requests from a lot of cars in the underground garage. To simulate the severe radio frequency signal loss and multipath fading features of underground enclosed spaces accurately, a programmable RF attenuator with a dynamic attenuation range of 0 to 120dB and a resolution of 0.1dB is employed in the signal attenuation module. Fault injection is performed by means of a hardware-level PCIe bus error injector, which can generate single-bit flips, multi-bit corruption and persistent link down events with a timing control accuracy of 10 microseconds; therefore, it is necessary to deterministically cause boundary fault conditions in routing nodes. The data acquisition and analysis software is DAQ-Suite v4.2, and IEEE 1588 Precision Time Protocol is used to make the distributed logs consistent in time. The routing nodes under test are in an isolated environment, running Ubuntu 20.04.3 LTS with the kernel version 5.4.0-91-generic; to reduce operating system jitter, real-time scheduling policies have been set up. In addition, the network structure of the nodes is composed of a redundant ring mesh with a 10 Gigabit Ethernet backbone to test the rerouting of paths when there is a link failure. Based on the above reasons, this parameterisation of the test platform is strictly according to the rules of reliability evaluation in the industry; therefore, the actual stress test environment can be completely recorded and will be subject to strict control and reproducibility.

4.1.2 Selection of typical routing node samples for underground garages

The selection of typical routing node samples is the first step in the process for the empirical validity and generalisation of fault tolerance stress testing. The basic idea of the selection is to be representative; the selected samples should cover all kinds of architecture and operations in the current intelligent underground garage market. Therefore, according to the requirement, three types of routing node products that have been applied in these environments are chosen: industrial-grade dedicated garage routing nodes, modified commercial wireless routing nodes, and customised Internet of Things communication nodes. Each category has different hardware topologies, different firmware optimisation strategies, and different ways to adapt to the environment, so it must be considered together to learn about all the vulnerabilities of the system under stress.
Within each of the three categories, three different samples will be selected from different manufacturers with different levels of market penetration. This cross-sectional sampling method is necessary to eliminate any manufacturer bias that may arise due to proprietary hardware tolerance or local firmware implementation. Based on the demand for large, medium and small market deployment volumes of the manufacturer's nodes, the experiment can be designed with a stable statistical distribution. Therefore, the selected nine samples form a small part of the whole industry. According to the above method, the fault tolerance indicators (packet loss rate for buffer overflow, delay decrease due to topology reconstruction, and the recovery time constant when a node fails in simulation) are not limited to a particular brand or architecture type. On the other hand, they can generally represent the resilience level of the current underground garage routing infrastructure, and therefore, they can serve as a good basis for later stress testing and system optimisation research.

4.2 Acquisition and collation of stress test original data

4.2.1 Data recording under gradient load increasing scenarios

Under the above conditions for the stress test of fault-tolerant nodes in underground parking garage routing, the first step is to collect and sort out the raw data from the gradient load increase process to be used as the basis for evaluating the system's stability. The basic principle of this process is to systematically obtain the dynamic response of routing nodes when external computing and communication demands increase. Operatively, a strict data recording system should be set up. It is necessary to record the specific values of all performance indices, including packet loss rate, routing recovery latency and throughput, for the benchmark group and verification group at all different load gradient stages. This is to ensure that all transitional states and critical thresholds will be recorded during the gradual addition of stress.
To ensure that the data set is objective and scientific, many trials and errors will be carried out as required by the operational path. In the test procedure, some abnormal data points will appear due to an accident or temporary changes in the environment, and not because of a failure in the routing node itself. Through several cycles of testing at each load gradient, the outlier points can be identified and removed to avoid biased statistics and ensure that the data truly reflect the inherent fault tolerance of the system. The average and standard deviation of each performance index under various load gradients are then calculated. The average value is the representative of the central tendency of node performance, and the standard deviation reflects the dispersion and stability of the routing node under certain stress conditions.
Finally, in the sorting process, we will create a corresponding table of load values and node performance parameters. Based on the above, a complete original data set is formed by systematically mapping the gradually increasing gradient loads to the calculated statistical indicators. The data set is very useful in practice, as it can reflect how performance changes with a gradual increase in load; thus, it is possible to determine precisely when the fault-tolerant function of routing nodes begins to fail under such a load and then modify the system's construction of underground parking garages accordingly.

4.2.2 Performance curve extraction under single-node and multi-node fault conditions

The extraction of performance change curves under single-node and multi-node faults is to verify whether the underground garage routing system is robust. The first one is to carry out a comprehensive collection of time-series data on all test indicators in three different operation stages: the normal state before faults, the transient state after faults, and the state after faults are repaired. Based on the division of time, it is able to accurately capture the shifts in the system's behaviour at different times and thus can be used as the basis for studying the fault tolerance of the system. In actual operation, fine-grained extraction is necessary to identify potential cascading failures and the causes of poor navigation in time for the engineers to respond quickly and avoid potential hazards due to changes in the underground environment.
The horizontal axis of the collation process is a continuous time sequence, and the vertical axis is a specific number. Through Cartesian mapping, the change curves of the data packet loss rate and response delay of the tested routing nodes can be accurately drawn. A single-node fault usually results in an isolated spike or decline in the affected node, while a multi-node fault will produce a combination of disturbances, showing the connection and influence between nodes as well as how well the distributed rerouting algorithm works. Through the path of the normal state, the occurrence of a fault, and the recovery to stability, these curves intuitively show how different node types respond to various fault vectors and the dynamic changes in their fault tolerance performance. Therefore, the obtained performance curves can show the range of resilience of the routing topology and prove that the fault tolerance model can operate normally in the event of random stress fluctuations.

4.3 Analysis of Test Result Validity and Performance Optimization Countermeasures

4.3.1 Credibility verification of stress test data against actual operation data

The verification of the reliability of the stress test data with the actual operation data is a necessary step to determine whether the simulated fault tolerance stress test can accurately represent the real-world situation of the underground garage routing nodes. To verify, we have obtained the actual operation data of a large-scale commercial underground garage for the past 30 days. The data contains all the various operating conditions of the routing nodes, and special attention has been paid to the situations at peak loads due to high traffic and frequent changes in the topology. The main basis for the above inspection is that when the actual peak load condition is met, the above-mentioned indicators of the relevant service level and the corresponding data of the simulation test platform will be relatively consistent. The key indicators to be compared are the packet loss rate, the time taken for the route to be restored after a fault has been introduced, and the rate of decrease in throughput. Calculate the degree of coincidence, that is, the proportion of the intersection of the probability density functions of the two data sets, to quantify how well the simulated stress test results align with the actual operational rules. The first way is to combine the time and space dimensions of the two data sets, use statistical hypothesis testing to reduce the error of the samples, and calculate the above degree of coincidence. Based on the above analysis results, there is a high degree of coincidence between the two sets of data; therefore, the results of the fault tolerance stress test performed by the designed system are very close to the actual operation rule. Based on this empirical evidence, it can be concluded that the test data are reliable and can accurately reflect the real performance of the routing nodes in the garage. The importance of this verification in practical applications cannot be overstated; it fills the gap between the controlled simulation and the unpredictable real world, ensuring that the following performance optimisation measures are based on reliable empirical data rather than the assumption of theoretical values. Therefore, the confirmed high fidelity of the stress test data proves that the proposed fault-tolerance mechanism can be applied in practice.

4.3.2 Classification of key fault tolerance bottlenecks of current underground garage routing nodes

According to the verified and valid test data, the main problems of fault-tolerance in the current routing nodes of underground garages are divided into four categories, and there will be different levels of performance decline in the event of a large number of people. The first one is the problem of insufficient computing resources, that is to say, the CPU and memory are not working properly in the case of a large number of accesses. When the number of concurrent requests for vehicle identification and path calculation exceeds the normal range, the delay of routing nodes will increase exponentially and there will be packet loss, showing that the problem of hardware resource allocation and task scheduling is severe. The second type is poor communication in the environment, and wireless channels in closed areas are not very good. The reinforced concrete structure of underground garages is prone to serious multipath fading and signal attenuation, so routing nodes will experience large fluctuations in throughput and intermittent link disconnections under high-frequency transmission stress, exposing a fundamental weakness in the physical layer's resilience. The third is the problem of state recovery delay, which is the time required to restore a node after it has failed. After an induced crash or hardware fault, the existing nodes will use sequential state reconstruction and routing table synchronization mechanisms, and thus take a long time for the network to converge. Therefore, the above reasons will lead to the network not working in time. The fourth is the problem of distributed coordination; that is to say, there are problems with the smooth transfer of loads between multiple nodes. When simulating node failure, due to the inflexible handover protocol and lack of topological awareness, the adjacent routing nodes cannot quickly redistribute traffic. Therefore, the traffic will be crowded in some areas and then spread to other areas in the form of cascading failures. Identify the main types of bottlenecks and their particular shortcomings in extreme conditions to find out what is wrong with the current routing architecture and provide a solid basis for the targeted optimization measures.

4.3.3 Targeted performance improvement strategies for routing node deployment and operation

It is necessary to propose targeted performance improvement measures for the construction and operation of the underground garage routing nodes, so as to turn the empirical stress-testing results into practical engineering knowledge. Based on the measured load boundary data from the fault-tolerance experiment, an ideal distribution scheme of node spacing can be determined systematically. Based on the above data, instead of relying on empirical estimations, the deployment topology should be adjusted dynamically to ensure that the maximum number of concurrent routing requests at any intersection never exceeds the empirically derived load ceiling; otherwise, there will be a local cascade failure and the complex underground space will lack all signal coverage. At the same time, in terms of node architecture, a priority optimisation method for the data transmission logic of the important service is needed. By separating the important vehicle-guidance and collision-avoidance data streams from the normal telemetry, the internal processing queue will have differential scheduling. Ensure that life safety and core routing packets have priority to avoid non-essential background transmission when the system is at high saturation and maintain a certain delay for important business. In addition, the limited space in the underground garage leads to greater crosstalk of wireless signals. To address this, a deployment-side adjustment scheme that includes physical and logical signal isolation for adjacent nodes needs to be developed. By orthogonally polarising directional antennas and allocating non-overlapping channels with spatial guard bands, mutual interference can be greatly reduced, thereby increasing the signal-to-noise ratio and stabilising the routing throughput under a high-density deployment scenario. Finally, in order to maintain the normal operation of the equipment for a long time, a daily operation and maintenance optimisation plan needs to be formulated, and a reasonable load alarm threshold should be set according to the recognised fault-tolerance bottleneck. The dynamic threshold is adjusted slightly below the stress-induced failure inflection point to allocate resources and dispatch predictive maintenance proactively before the system goes into an irreversible degraded state. Therefore, these strategies will be used to guide the construction of an underground garage routing system by using both the theoretical fault-tolerance limit and the actual deployment conditions.

Chapter 5 Conclusion

To investigate the fault-tolerance stress test of routing nodes in underground garages, we will make some theoretical and practical contributions in this paper. In short, fault-tolerance in this environment means that the system can still run normally and route messages according to rules even if some nodes fail or there is a problem with communication. After studying the basic ideas of distributed path resilience and dynamic topology change in depth, it can be concluded that under the communication constraints of a typical underground facility, there will always be a way to recover from a particular type of fault. The operation procedure developed in this paper is to inject a variety of fault vectors, such as hardware failure, signal loss, and data packet conflicts, into the routing network in a controlled manner [5]. The methodology precisely defines the limits of network isolation tolerance and the speed of algorithm convergence by gradually increasing stress. This is a workable way to examine the robustness of adaptive routing algorithms before they are deployed in practice. Therefore, it is important. In an automatic parking system, if one routing node fails without being noticed, there will be a traffic jam in the vehicles' paths, the route will be incorrect, and there may be a safety accident. Based on the proposed stress test scheme, system architects can detect hidden problems in advance, verify whether redundant paths will be used after node failure, and ensure that the backup topology meets the requirements for low latency and high reliability as specified by the industry. The empirical data shows that there is a close relationship between the redundancy of nodes and the computational cost of the algorithm; thus, we can allocate resources more reasonably in large-scale deployments. Finally, this research will connect the theoretical fault-tolerance model with the application of vehicular network engineering and guarantee that the underground garage's routing architecture has sufficient resilience to keep running smoothly under adverse working conditions. The approved stress-testing program will also be used as an important engineering safeguard to systematically check the reliability and fail-safe working continuity of intelligent transportation systems.

References

[1]刘海波, 雷冰冰, 王晓峰. 基于改进蚁群算法的AODV路由协议优化[J]. 计算机应用与软件, 2026, 43(2): 141-146.
[2]康万杰, 潘有顺, 陈秋菊. 拟合定位下的通信路由故障自修复组密钥控制研究[J]. 淮阴师范学院学报(自然科学版), 2026, 25(1): 21-25.
[3]Walid Najjar, J.-L. Gaudiot. Network resilience: a measure of network fault tolerance[J]. IEEE Transactions on Computers, 1990.
[4]Muntadher Saadoon, Siti Hafizah Ab Hamid, Hazrina Sofian. Preliminary Exploration on Node-To-Node Fault Tolerance Coordination in Distributed System[J]. 2023.
[5]Mei-Chen Hsueh, Timothy Tsai, Ravishankar K. Iyer. Fault injection techniques and tools[J]. Computer, 1997.
[6]Jakub Przybyło, Andrzej Żak. Largest Component and Node Fault Tolerance for Grids[J]. The Electronic Journal of Combinatorics, 2021.
[7]Zbigniew Kalbarczyk, Ravishankar K. Iyer, Saurabh Bagchi. Chameleon: a software infrastructure for adaptive fault tolerance[J]. IEEE Transactions on Parallel and Distributed Systems, 1999.